| Model |
YHIG-200K-0.2KJC |
YHIG-200K-1KJC |
| Operation Panel |
| Input voltage |
Single phase
200V
50/60Hz |
| Capacity |
5kVA |
| Output voltage |
AC 0-200V 3kVA
Controled by AC chopper power supply |
AC 0-200V 5kVA
Controled by AC chopper power supply |
| Interface |
GP-IB & Optical fiber |
| AC,DC High voltage generator(Oil type) |
| Input voltage |
Single phase 200V 50/60Hz |
| Other |
With automatic discharging system |
Output
(AC/DC switchable) |
AC50kV 60mA
(rated 30 min.) |
AC50kV 100mA
(rated 30 min.) |
| DC+/-50kV 20mA
(rated 30 min.) |
DC+/-50kV 20mA
(rated 30 min.) |
| Ripple |
Within2%p-p(50kV 5mA) |
| Output Voltage Accuracy |
5*10-5(Input voltage +/-10%/5mA) |
| Other |
With AC/DC , Positive/Negative and grounding devise |
| Impulse voltage generator |
| Input receiving voltage |
DC0-+/-50kV |
| Nominal impulse generation
voltage |
+5kV-100kVp |
+5kV-200kVp |
| Total electrostatic
capacity |
0.0125microF(0.05microF*4S) |
0.0625microF(0.25microF*4S) |
| Maximum receiving energy |
625WS |
1.25kWS |
| Generated waveform |
1.2*50microS |
| Output polarity |
Positive polarity/Negative polarity(electric switch) |
| Impulse voltage measuring unit |
| Ball gap |
125mmsq |
| Gap scale |
0-100mm |
| measurable
voltage |
16.8kVp-215kVp |
| Insulator tester |
| Oil tank |
W300*D300*H200mm |
| Electrodes |
Sphere20sq/Plate50sq/Needle |
| Other |
|
Digital Oscilloscope (DL1520) |
| Accessories |
|
Personal computer /
Printer /
Oil cup/grounding
bar/Suspension insulator
Power code/High voltage side wiring cord and neon cord |
| Option |
|
High voltage probe(DC100kV
Pulse voltage 200kV) |